The first suspicion
for pressure drop problems on arc spray is that the spray is coating the
cartridge, since the compounds have not lost there coating characteristics
before they reach the surface of the media and seal or partially seal the surfaces.
This is referred to as “painting effect”.
The symptom of this
is that the pressure drop goes up quickly within 20 minutes. It does not
recover from on line cleaning. The pressure drop for off-line cleaning
quickly ratchets until the you get to the top of the hump in the fan curve.
We ran some tests on
an operation in Atlanta about five years ago where we installed a pilot unit
with varying lengths of pipe and found on that operation that it required 0.8
seconds of transit time from the spray gun to the surface of the cartridge
filter elements, to prevent “painting”. Other reports that we received from
Torit installations reinforced our conclusions. They sprayed aluminum,
titanium, nickel, and ceramics. They were coating turbine blades for jet
airplanes.
The observation of very fine dust floating
in the collector, when the fan was off, can be very significant. It would be important
to observe whether the same was evident in the clean air plenum. If it was, I
would want to question the efficacy of the filter seals. The next possibility
that this observation raises is whether the dust agglomerates on the media
surface and/or stays agglomerated during the cleaning cycle. If it does not
stay agglomerated during the cleaning cycle the coarser agglomerates will fall into
the hopper and the finer fractions will return to the surface of the filter
media. This will cause a ratcheting of the pressure drop at each cleaning
cycle.
It was also observed a
gradual increase in pressure drop. This can be caused by the lack of agglomeration
as described above. However if this is the cause, the collector should return
to initial pressure drop after an extended cycle of off-line cleaning. We
would say that you need to put fifteen minutes off time and pulse the collector
four times.
There are other
processes that might have some of the symptoms. Among them:
Oil in
the compressed air. If they
have a screw compressor there is a filter that comes with the compressor. Sometimes the installer
forgets to put it in. With pneumatic cylinders, the air line cleaners are sufficient to allow suitable operation.
Moisture
in the compressed air line. Here
again they should have a refrigerant or a desiccant dryer.
Condensation
on the media surfaces because
of the cooling of the cleaning air jet. If the latter is the case, the pressure drop
increase will generally be apparent more likely in the morning when the difference between the dry and wet bulb
temperatures are most likely to occur.
Replacing a third of
the cartridges is generally not a good idea. It is also important which ones
you replace. If they are tandem cartridges I would replace one on each tandem
set. Personally, if I were to replace cartridges to run a test I would replace
the ones furthest from the pulse-jet orifice/nozzle. When you do that, you do
not even need to initially clean off-line. I figure you are wasting most of
your media in a tandem configuration so when you replace cartridges on a
trouble job, it is smart to replace only the outer one.
We need to determine
if the cartridge is plugging from the dirty side or the clean side. We assumed
it was from the dirty side but the clean side is a possibility. We usually
check to see if there is any dust in the clean air plenum. If there is, the
problem may be the seals. You may need special seals for this fine submicron
dust.
For assistance with a trouble job... Technical assistance with dust collectors