Moisture and Freezing in Pulse Jet Dust Collectors

The root of the problem comes from the fact that as you compress air the moisture holding capacity decreases. Compressors have after coolers in which most of the condensed water is removed before the compressed air enters the distribution system. The compressed air is usually a bit higher temperature than the ambient temperature. As it flows from the compressor to the machines some additional water will condense. Usually any large droplets will be collected in the air line filters before they reach the machines. There is still some moisture but it does not affect the operation of most machines. On other machines where this remaining moisture is undesirable or harmful, dryers are installed between the machinery and the compressor. On compressed air powered pulse jet collectors, the presence of liquid moisture in the pneumatic lines can have serious effects:

  1. The water can collect in the compressed air manifold. When sufficient water is collected, it may “squirt” into the filter elements during a cleaning cycle. The drenching of the filter elements is intermittent, but the long term effect is higher pressure drop, more frequent cleaning and premature filter element replacement. Often the filter will dry itself from the exhaust flow through the collector. But residual effects from this wet dry cycling are cumulative. Cellulose cartridge filter elements are especially vulnerable as each wet cycle causes the permeability to increase and harmful effects are much faster.
  2. If a collector is installed outdoors in below freezing conditions, even very small amounts of moisture droplets can condense on the diaphragms of air valves. The diaphragms will then stick to the seats of the valves and will not close. This will discharge all the air from the system, since typically 150 to 400 SCFM can be discharged through the valve. Since these valves operate with internal pilot ports, the valve will not close until the supply pressure reaches 25 psig. There needs to be an external shutoff to get the collector (and sometimes associated compressed air supply) back to an operating mode.


Quality Air Management has a two different products to address these problems:

  • Manifold Tank Automatic Drain Valve System
  • Thermostatically control compressed air manifold heater. This system will allow the collector to operate even when the compressed air dryer is malfunctioning by turning any liquid moisture to water vapor.


QAM also provides dust collector retrofit and consulting services to help resolve common problems that no one else seems to have found solutions.

Wednesday, April 20, 2016

Welding Laser Plasma Arc Processes Causes Major Problems

Welding laser plasma arc processes include welding fume capture, plasma and laser cutting tables, thermal spray operations. Each of these present unique and difficult issues that will cause a dust collection system to fail.

Welding

Two Stage Electrostatic Collectors; Venting welding fume operations poses some difficult application decisions. Years ago, the preferred method of collecting weld fume was with two stage electrostatic precipitator dust collectors. These had several advantages; they were relatively compact and were generally very effective on general ventilation applications. They could handle relatively large gas volumes through the collectors and generally were located near the roofs of buildings.

Efficiencies of general ventilation; The collection efficiency was variable depending on the velocity going through the collection plates. The lower the velocity through the collectors the higher was the collection efficiency. The same collector might have an 80% collection efficiency at 6,000 CFM and a 98.5 % efficiency at 1,000 CFM The same collector could be applied to different exhaust volumes that would vary as much as a ratio of 6:1. The higher the volume would produce the lowest efficiencies. But the same air would be re-circulated and an acceptable level could be maintained in a particular room or building. The cleaning of the precipitators were accomplished by a detergent wash system.
Loading for general ventilation; The loading for general ventilation units were from 0.1 to 0.5 grain per thousand cubic feet of volume. The washing frequency was typically once or twice a week. The presence of condensed hydrocarbons along with the fume was not a problem. Generally these would be oxidized into solids by the time the filter was washed. These collectors were generally the same ones that were applied as air filters in HVAC systems. The washing systems were designed for 1000 cycle life. This would translate to over ten years of life under these low loading conditions.

Hooded Systems; The trend was to hood the welding operations. The venting of hoods had some pronounced effects on the application of these precipitators. The load would vary from 5 to 20 grains per1000 CFM.

Effects of hooded systems; Usually the washing requirements were to wash the filter every shift or twice per shift because the load was so much higher. On a two shift operation, and washing twice per shift, the washing system had a life expectancy of less than 52 weeks.

Plating; It was necessary to operate particular precipitators at lower volumes with their associated higher efficiency, because of a phenomenon called “plating”. Referring to figure 1, the precipitator will ionize the gas and the welding laser plasma arc particles. As the dust passes through the precipitator it forms a bubble type shape, containing charged particles, which were not collected on the collection plates. The gas quickly loses it’s charge. However the dust that was not collected keeps it’s charge a little while longer and loses its charge as it leaves the boundary of thebubble marked “A” in figure 1. If the precipitator has a low efficiency the bubble is much bigger as marked by “B”. This low efficiency bubble is 2 to 20X as bigger in volume than the high efficiency bubble.
Under certain atmospheric ambient conditions, this low efficiency bubble starts to grow rapidly until the whole room atmosphere is ionized and the room and all the contents become collection plates for the dust. The dust s attracted to the walls, windows, machines, eyeglasses and every object that is grounded. All the surfaces turn blackened within seconds. There have been cases where this happened after the walls were painted white. After the atmospheric conditions go back to normal the plating stops.
Bad Inlet conditions. All precipitators either single or two stage need even velocity distribution across the plates. If we had a gas stream averaging 100 fpm that would be designed to operate at 95% collection efficiency and the real velocities entering the plates varied from 50 to 150 fpm, the section at 50 fpm might have a collection efficiency of 98% and the section at 150 fpm would be running at 80%. This would mean that the overall efficiency might operate at close to 85%. This condition would cause phenomenon described above
Lower Efficiencies, caused by running at lower average velocities were common. In the example above the collector might be selected to run at 125 fpm and an average efficiency of 85%. Plating may be produced because of these lower velocities and lower collection efficiency. As a result, many collectors were purchased based on volume and the supplier’s guaranteed higher collection efficiencies. There were practically no way to specify the collectors except based on supplier claims. Velocity was not a good criterion. Some collectors at relatively higher velocity and longer sets of collection plates would achieve the same result as a collector with short plates and a slower velocity.
Electrical Controls; To further aggravate the problem improper electrical controls were offered. Some operators interpreted SIC controls to mean arcing was not allowed. To eliminate the arcing across the plates, they lowered the voltage controls to halt this sparking. Unfortunately the voltage was lowered so much that the particles were not charged. There were cases where the metal pre-filters were more efficient than the precipitators.
Insulator Coating; The main collection plates are at ground in a two stage electrostatic precipitators. The charged particles will be attracted to the lower voltage intermediate voltage level plates and to the grounded collection plates. The insulators were also at ground level and some of the dust (a very small percentage) stuck to the surface of the insulators. This was a very strong bond and the spray cleaning systems could not keep these insulators clean. Eventually they were coated badly enough that the power supply could not keep the charging electrodes to ionize the gas and the particles. To correct this problem required a major overhaul of the precipitator. The charging electrodes were made of very fine wires and would eventually break and require replacement. Most electrical maintenance men were not familiar with high voltage supplies and maintenance was neglected.
Innovations in Design; In the late 70’s, two stage precipitators with pressurized insulators and more rugged washing systems were introduced. The insulators were subject to a gas stream that entered the collection compartment at a higher velocity than the collection velocity across the plates. This protected the insulators from charged particles. The charging electrodes were made heavier to give much longer charging electrode life.
These innovations increased the collection costs with electrostatic collectors to the point where cartridge dust collectors introduced at the same time were more economical to purchase and operate.

The advantages of the electrostatic collectors were:

  1. The pressure drop was constant and usually low.
  2. They could collect liquid droplets.
  3. They had the potential of long periods of service without maintenance.


Cartridge Dust Collectors

With the development of cartridge collectors, another method of collecting fume dusts became available. The standard design pulse jet fabric collectors with cylindrical bags did not work because the cleaning systems propelled dust through the cake of adjoining rows of bags during the cleaning cycles. In the late 70’s and early 80’s thousands of cartridge collectors were applied to both hooded and non-hooded ventilation systems.
Problems developed in many systems after the mid eighties. High-pressure drops and short cartridge life developed in many systems. The causes were one or more of the following:
The presence of thin films of oil on the surface of the parts that were welded. When electrostatic powder coating finishing systems were widely applied to reduce or eliminate hydrocarbon generation from paint systems, the faces of steel parts required protection from oxides on the surfaces. During the welding process condensing hydrocarbons were liberated and swept up into the ventilating systems and their associated collectors. One of several results followed:
a) The solids to liquid ratio was so high that the dust blotted the liquids and the collection system was not affected by the liquid droplets.
b) The solids to liquids ratio was in range where the powders and hydrocarbon mixture formed a paint and the collection media was gradually plugged. This could take days, weeks or months, but the net effect was the cartridges had to be replaced or laundered pre-maturely.
c) The solids to liquid ratio was so low that liquid wetted the cartridges and they were plugged as in (b) above. Even in cases where the coating was barely discernible, this could occur.

A case in point was in a plant making stainless steel mufflers. The metal was washed after forming and the load in solids was 0.02 grains per 1000 CFM, the pressure drop rose in a six month time period. The re-enforced cellulose media would be air-dried and the pressure drop would be reduced from six inches to 0.3 inches after the elements were installed. After 4 months the pressure drop went up to six inches. After washing the pressure drop went down to 0.8 inches. The next washing cycle came two months later and the pressure drop returned to 1.2 inches. It was less expensive to replace the cartridges than to wash them in such a short interval.

Washing cellulose media cartridge elements: After each washing, the media is wetted, the permeability of the media diminishes, even if no dust remains at or below the surface of the media. The wetting causes the media to matt. If oil wets the media it is a good blotter and the fibers may grow. This causes the pressure drop and base permeability to decrease.
Other media are available that can be washed and are not wetted by oils. These are referred to as oleophobic media. This is a coating on the fibers that does not change the permeability. Otherwise they will be called washable. Often they can collect a mixture of fumes and hydrocarbons because the fibers do not swell.
Treated Spun bond medias are widely applied. Some of these are excellent choices but have limitations. For instance, with tight pleats, the top of the pleat may squeeze so the media in that portion of the pleat may make contact on the clean side when the pressure drop rises. On some applications, over 80% of the pleat of the media may not be effective. The remedy is one of the following.
A) Provide pleats with wider spacing and make them shorter in depth. This will allow full use of the media available in the filter element.
B) Provide a media that has stiffness and will not collapse on itself.
C) Provide a laminated media with the clean side backing very open so that if the pleat squeezes there will be flow through the media.

De-agglomerating dust; Normally we would run a properly designed dust collector at 1 to 1.5 inch water column pressure drop. Sometimes a system will only stabilize at a higher reading (E.G. 3 to 4 inches). One possibility is that it takes 3 to 4 inches to cause the dust to agglomerate and fall to the hopper. It may be de-agglomerating when you pulse at lower pressure drops. In that case off-line cleaning should drop out the de-agglomerating dusts. Some dusts are more susceptible to this phenomenon than others. Often, they put an anti-rust wipe on the material being cut. If it contains ceramics then we will have this problem.


Fume Generating Processes Similar to Arc Welding and Gas cutting


Thermal Deposition Processes

Spray Coating The first type was a flame spray coating machine. These fed a material into a high heat gas torch. The temperature achieved was so high that feed material would produce a material in gaseous/liquid form that started to condense into molten droplets. Though the process is not understood, it is presumed that some of the adhesion was from a nuclear bonding, in addition to the cooling of the molten droplets on the piece to be coated. There were some materials that were too porous and there was limits to the thickness of the coating. The over-spray that did not adhere varied from about 5 - 20% of the material fed into the coating generating gun. The over spray was generally collected by medium pressure air washer scrubbers at a 99% collection efficiency.
Plasma Arc Spray To get smoother surfaces and better adhesion to the target surfaces, an electric arc was added to gas flame. This produced much higher temperatures in the gun at the point where the powder or wire feed entered. It generally produced more over spray (10%-40%). This over spray was much finer and would lose its ability to stick and adhere to surfaces. This over spray was too fine to be collected efficiently with air washer wet scrubbers. Fabric or pleated cartridge collectors were necessary.
One serious problem was encountered. This involved residence time of the dust between the gun and the media collection surfaces. In a system installed in 1975, on a plasma arc spraying machine for coating electrical capacitors. The process was coating plastic surfaces with metal. The cartridge collector filter elements, venting the over spray, plugged up in less than ten minutes. The six cartridges each with 50 square feet of filter, (300 sq. ft. total) received less than 250 grains of dust. The dust collector was connected within 20 inches of the gun. The over spray dust adhered to the media surface and blocked the pores.
Through experimentation and field experience it was determined that if the dust stayed in the gas stream for relatively long periods of time, it would lose its ability to coat the media. Depending on various factors such as the feed rates of gas, solids and the arc current, this time varied. It varied from 0.5 to 1.0 seconds. Referring to the next figure, the residence time will be analyzed.
The part to be coated is placed in a hood with the gun at the front of the hood. The hood is 6 foot long and is rectangular with a 4 x 4 opening. The face velocity of the hood is 350 feet per minute. The duct is sized at a 2500 feet per minute duct velocity and the duct is 15 feet long. We will assume the back of the hood has a transition 2 foot long, designed like an evasé to have uniform velocity distribution.
1) Time to travel through the hood 6 ft / 350 FPM = 0.017 seconds
2) Time to traverse duct to the collector 15 ft / 2500 FPM = 0.006 seconds
Residence time = 0.017 + 0.006 = 0.023 seconds.
The flow through the system is 350FPM x 16 sq. ft. = 5600 CFM

To re-design collection for longer residence time the length of travel in components are altered and the velocity can be modified. The hood is the first to be looked at.
3) The hood would be made 10 foot wide with the same 4 foot by 4 foot opening for the gun and part. The velocity in the wide part of the hood would be 5600 CFM / 100 sq ft = 56 FPM
The residence time in this portion of the hood would be 18 feet divided by 56 FPM = 0.32 seconds.
4) The duct could be extended to 200 ft by putting in ductwork in a “serpentine fashion” and enlarged to drop duct velocity to 1,000 FPM. The residence time in duct would be 200 feet/ 1000 FPM = .0.20 seconds

The residence time of the system would be 0.32 + 0.20 = 0.52 seconds.

High Temperature Cutting Processes


This high temperature flame coming from the gas gun proved to be an excellent improvement in flame cutting. Instead of jagged edges near the cut, it became much smoother and for most applications it did not require smoothing the edge or the operation was very quick. With digital cutting machines the precision rivaled other cutting processes.

Plasma cutting and laser-enhanced cutting are in common use. The type of dust produced runs the gamut from arc welding to that of metalizing operations. Most dust is more similar to venting systems for arc welding operations, but to get some cutting characteristics the temperature and flow in the gun are adjusted. This may produce a dust that is prone to coat surfaces and media. When this happens the residence time requirements may be in the same range as the electro deposition processes. Laser cutters work well with 1 second residence time. Some flame cutters have been applied to non-metallic pieces such as wood and plastics. These dusts can contain tars, and oils from non-metallic parts and the collector media can get plugged easily, within a few seconds. With metallic parts, the oils can be an imperceptible film on the metal or originate from the compressed air compressor. In that case, a low-pressure scrubber may be a good choice. Roll filters with replaceable media or a self-feeding pre-coat material system have been employed.
It is crucial to have the correct airflow at initial start-up. Too much airflow will reduce residence time and cause the painting effect. Install a control damper in the main duct and use an approved method to accurately measure the exact airflow. Use the damper to choke the system if needed.
Recently, it has come to our attention that some plasma cutting processes are throwing out the 1 second residence time rule of thumb. Either the process temperature is being cranked up so high that the molten metal atoms still don’t have enough time to form molecules or the dust concentrations are so low that the atoms never get a chance to collide with one another in the laminar flow of the duct system. In these cases, finding the correct residence time
is almost a trial and error process. A new product has come on the market, called a Quencher, which is inserted in the ductwork as close to the source of dust as possible and no less than 10 duct diameters upstream from the collector. This device imparts a high energy multi-directional swirl to the air stream which cools the metallic atoms, accelerate their oxidization, and forces them to collide together and form molecules which can safely be collected without the painting effect.

Use the links below to obtain more information on welding laser plasma arc applications.






Thursday, September 24, 2015

Shot Peener and Blasting Operations


The abrasive generated dusts have some unique properties that need to be addressed to accomplish the following by application of advanced technology dust collector designs:
1)    Lowering the dust penetration through the filter cake filtering mechanism will protect the environment and employees.
2)    Re-circulation of the vented air can reduce energy consumption.
3)    Further economic savings, by lowering energy consumption, for operating the vent system at lower pressure drops and reducing pulsing air consumption.
4)    Filter life can be increased by 3 to 4 times.
 
For many years, abrasive blast operations were vented from the blast cabinets through mechanical shaker dust collectors. In these units the initial collection efficiency was relatively low. As the cake became thicker, the pressure drop increased. It would eventually increase so high that the flow through the system would be choked. 

Several mechanical arrangements to remove excess dust were development. During the process of removing the dust, a portion of the dust remained on the media. This residual dust had formed a filter cake and even after cleaning the collection efficiency was high enough to allow re-circulation. In the early 1960’s continuous cleaning pulse jet collectors were introduced. These collectors were much smaller than the mechanical cleaning collectors and reduced the complexity of the venting duct-work. The typical collector was 15-25% of the size of the compartment-ed mechanical cleaning collector. However, the average particulate load penetrating through the collector was about 2.5 milligrams per cubic meter, which could not be re-circulated into the working environment.

In 1973, pleated filter elements were introduced into the dust collection market. It was believed that pulse jet collectors would be more efficient if they were pleated because of low velocities through the filter element. Most dust collector manufacturers and designers packed too many pleats in the cartridge filter element. Also, the cleaning system was undersized for the amount of media at that must be cleaned.  The result is dust bridging on the inner pleat.  In many cases, we can lose up to 80% of the effective workable area of filter media.  This led to short filter life and high maintenance cost.

Advanced technology modifications have improved the operations of each of these types of collectors, reducing the foot print, lowering pressure drop (with lower power consumption) and reducing penetration of dust through the collectors. The next breakthrough in the advanced technology reverse pulse jet designs came in the realization that the capacity of a filter element depended on the reverse air volume of the cleaning jet. More volume could be applied per filter element and the footprint reduced drastically.
 
Cleaning System Designs must be sufficiently sized to develop the required volume to vent the process. The most volume that can be filtered depends on the number and size (or equivalent size) and number of valves. The advanced technology uses a proprietary supersonic nozzle design which increases the reverse jet flow by 70 per cent over a conventional orifice by getting a more efficient pressure to velocity conversion.

There are several considerations for safety and reliability that must be taken into account.

View and print ... Shot Peeners (PDF)
Read more about ... Advanced Technology pulse jet dust collector

Thursday, July 2, 2015

Blinded Filter Bags

This is an Ultra-Flow 60 bag advanced technology baghouse dust collector, collecting rubber, fiberglass fiber and metal slivers from two hammer mills, in a tire recycling plant.
Baghouse filters problems
Problem: Dust bags started out at 1-1.5”wg pressure drop, then, rose to 7-7.5” in a short space of time. Cleaning off-line only reduces the pressure drop to 5-5.5”wc. Then a third set of bags, installed a year later, started at 4”wc and clogged (7-8”wc) in 2-3 hours.

Observation (first set of bags, June 2, 2009):
        I.      There was no indication of leakage from the dirty side to the clean side of the collector.
      II.      A bag was sent to our testing lab for analysis. The findings were;
a.       Confirmed no leakage of the bags.
b.     The bag was totally blinded on the dirty side. It was a paste-like dust cake. It is also an indication of moisture in the process getting onto the bags.
c.        The bag was cleaned well but permeability was still low at 2-4 CFM. This indicates chemical attack of the media, likely from some kind of solvent. That renders the bags not recoverable.
   III.      Further very deep laundering of the bag with a surfactant started recovering the bag and increased the permeability to almost the “as new” state. This revealed that instead of chemical attack, the pores of the media were being “painted” making the bag coat with a sticky substance. No dust collector cleaning system can handle paint, blinding the bag media. There is likely rain, snow, road tar and solvent coming in with the tires. This moisture, when heated by the action of the hammer mill, would create latex and/or solvent based paint that got onto the bags. This situation would be intermittent. Once the moisture got through and the process dried up, the paste/paint on the bags would dry out also, leading to the false conclusion that the dust collected was dry.
  IV.  A subsequent squeeze test of the dust collected, alone, revealed no presence of oily substance, leading us to conclude that the painting is caused by moisture (water or snow remaining in the tires when put through the hammer mill.
Solution:
      II.      Teflon bags would resist solvents. We would advise Teflon impregnated bags, not membrane (i.e. Gortex), to keep the permeability at a manageable level. The use of Teflon membrane would require de-rating the dust collector performance by 50%.
   III.      Too much heat may be generated at the hammer mill which can be corrected by using a current controller (instead of a voltage limiting speed limiting controller) on the drive, producing a powder instead of paint. Also an inert dust could be fed in as pre-coat to make it a powder cake instead of a gooey coating.
    IV.      Same as III.

Observation (third set of bags, April 2010):
  1. These bags no longer displayed the wetting and hydrocarbons of the first set, due to corrections in the process. The polypropylene bags, from a new supplier, appeared heavier and glazed on both sides of the bag material.
  2. The snap band collar was uniformly dirty, not just the part below the tube-sheet groove, and there was dirt on the inside of the bag. This was an indication that the bags were installed wrong. Instead of snapping the band’s groove into the tube-sheet edge, they laid the snap band on top of the tube-sheet. That created a loose fit and a large leak of air from the dirty chamber to the clean air chamber. Each pulse would blow dirt back down into the bag, coating the clean side with dirt. This negated the cleaning system by blinding the bags.
  3. The hopper was being discharged into a porous bag instead of the original sealed bin. This results in the air being drawn up through the discharge into the collector. The upward “can velocity” hangs up the dust into the collector and causes the dust to be re-entrained onto the bags during a cleaning pulse and will not drop to the hopper and bag below. When we opened the access door on the hopper a large amount of dust would drop to the bag when the suction was released at the discharge.
  4. A replacement set of polyester bags had a high 4-5”wc initial pressure drop when installed.
Solution:
  1. Our testing laboratory confirmed that the bags, when clean, were 5-10 cfm permeability instead of 25-35 as specified for those bags. That accounted for the high initial pressure drop. The test also confirmed that we now have normal dry rubber dust and none of the sticky stuff from before. A new set of bags was supplied, under warranty, switching back to the standard singed polyester material since moisture was no longer an issue. Polypropylene was supplied for the second set to account for the moisture getting in the process, at the time.
  2. The new set of bags was supplied with our standard o-ring seal. In this way, the bags could not be installed improperly, creating a reliable seal at the tube-sheet.
  3. The hopper discharged was sealed by a rotary air-lock which prevented dust hanging up in the hopper and filter bags.
  4. The new set worked well. The initial high pressure drop reading was the result of a clogged air line filter to the magnehelic gauge. After cleaning out the filter and air line, the false reading came back to the normal 1.5”wc.

Monday, June 15, 2009

Condensation in Dust Collectors

Let's look at three service reports which illustrate the problems of condensation and outline the possible solutions.

London, Ontario Installation;

Cartridge Dust collector retrofit on Plasma cutting stations
The client complained of having to service the cartridges every 1-2 days because they would plug up. The pressure drop across the collector would rise to 8-10 inches water column. The cleaning system was totally redesigned, and six 36” high ratio style cartridge filters replaced twenty-four 26” tandem cartridges. 80/20 paper blend cartridges were installed temporarily until special anti-pinch style polyester filters could be supplied. Within two days the paper cartridges blew apart, mostly at the closed end-cap. They did run the pulsed cleaning system at 100psi instead of 85psi, with no regulator on the line. However, that was not enough to rip the media apart, so, something else was the cause. Upon inspection of the cartridges, we observed that the media was dry but had the look of being wetted. Also there were watermark stains on the clean side of the media. There was an accumulator tank on the compressed air line leading to the collector. The maintenance people told us the accumulator was installed because the valve manifold wasn’t large enough to hold enough residual pressure during a pulse. The manifold was just fine. What was happening is that the air line was very long (over 200 feet) from the compressor to the collector. Moisture would condense in the line then drop out at two elbows, which was the low point just before going up to the manifold. This choked the line which made the manifold appear like it was too small, and then suddenly a slug of water would blow through to the valves and into the cartridges. We recommended taking out the accumulator tank and, just before the connection to the valve manifold, installing an air line coalescing filter, top quality dryer, and a regulator set for 85psi. We also recommended an automatic drain valve system on the manifold tank. The collector now runs continuously at 3-3.5inch pressure drop. The client says they’ve never been able to control the contaminants at the plasma stations so well since they installed the system 1.5 years prior to the retrofit.

Maine Installation; Energy Recovery from Trash and garbage.
This collector installation was venting a large room where garbage was dumped. Front-end loaders took this garbage and carried it to the hoppers that fed an incinerator. Steam was produced that fed a boiler. The pulse jet collector vented 65,000 ACFM at ambient conditions. It was running at a 15:1 filter ratio and at 2 “ water column from January to June. In June the pressure drop started to creep upwards about 1/8 of inch per week. This collector was well instrumented with continuous recording of wet bulb and dry bulb temperatures as well as pressure drop. We compared the pressure drop increases with the weather reports in the local newspapers. The increases occurred early in the morning on days when the wet bulb and dry bulb temperature were closer than 5 degrees F. There were several kinds of trash being handled in the facility. We recommended that they not load the wet trash into the incinerator until after 10:00 a.m. This stopped the rising pressure drop problem. Since they shut the system down on weekends we recommended that they clean the collector for two hours on Saturday afternoon with the outlet fan damper 90% closed. This was almost as effective as off line cleaning and the dust was not blown back into the loading room during the procedure. The dust collector ran for at least two years, at less than three inches water gauge pressure drop after implementing these recommendations.
General Comments The cleaning system was running at 85 psig. Under typical conditions the compressed air expands to critical pressure which is 37psig. beyond this pressure, the pressure to velocity conversion stops and from 37 psig to atmospheric pressure, 0 psig, the energy is turned to heat from turbulence. This nullifies the refrigeration cycle as the compressed air expands to critical pressure. This collector used converging diverging nozzles which had a complete conversion of pressure to energy so that the refrigeration cycle was reducing the temperature in the jet by approximately 5-8 degrees F.
Actually the turbulence below 37 psig causes some heat regain but the jet is still 5-8 degrees cooler despite this. Without the regain it would be about 9-12 degrees cooler. With a converging diverging nozzles the amount of cooling from expanded compressed air in the jet is a bit colder but the amount of induced air from the plenum is almost twice as much as with an ordinary orifice so the jet temperature is about 6-8 degrees cooler but not enough to make a difference. In Maine, the problem was mainly in the summer when the trash was wet from people dumping beer and other associated liquids. They did not have the problem in the winter when the trash was dry.
There were two other approaches that could have been used to counter the rising pressure drop:
1) Larger pulse valves and eliminating the nozzles. However, this would increase air consumption by over 35%.
2) Manifold heaters could be installed that would raise the temperature of the cleaning jet above ambient even to the point where wet garbage could be processed in high humidity conditions.
In either case, the collector could not handle vent volume where the gas entering the collector has condensed water droplets.
Low pressure compressed air, in the range of 7 to 22 psig is often employed for pulse jet cleaning systems. These have the same effect as the cleaning system with converging diverging nozzles since no turbulence occurs as complete expansion occurs in the orifice or nozzle. The best remedies are as follows:
1. Locate the low pressure compressor near the pulse valves and insulate the manifold leading to the pulse valves.
2. Use a manifold heater in the compressed air header, same as described above.
Other Comments and observations. There are many other installations in energy recovery plants that use high ratio reverse air fan collectors, The temperature regain on the reverse air fan is higher than ambient and eliminates condensation considerations described above.

East Tennessee Installation; Powder coating
This plant in the upper elevations in the mountains used a pulse jet collector to vent a powder coating operation that coated the internals of residential wash machines. This pulse jet collector started in July and ran until the middle of the winter when it developed a creeping rise in pressure drop characteristics. The wet and dry bulb spread was usually over 15 degrees F except early in the morning when it was about ten degrees. Investigation of the operation was conducted and we measured wet and dry bulb temperatures with a sling psychrometer mounted through a hole in the main vent duct. What we discovered is the booths were manually washed with a hot water hose every morning. At times the gas would go through the dew point for several minutes and then immediately go back to operation at a wide dew point spread. We recommended mounting a heater with a damper on a branch line to the vent system. The heater was triggered by pressure switches on the hot water hoses in each booth. This eliminated the creeping pressure drop problem permanently.

For information ... Dust Collector retrofits and Troubleshooting 

Thursday, June 12, 2008

Moisture and Freezing in Pulse Jet Dust Collectors

The root of the problem comes from the fact that as you compress air the moisture holding capacity decreases. Compressors have after coolers in which most of the condensed water is removed before the compressed air enters the distribution system. The compressed air is usually a bit higher than the ambient temperature. As it flows from the compressor to the machines some additional water will condense. Usually any large droplets will be collected in the air line filters before they reach the machines. There is still some moisture but it does not affect the operation of most machines. On other machines where this remaining moisture is undesirable or harmful, dryers are installed between the machinery and the compressor. On compressed air powered pulse jet collectors, the presence of liquid moisture in the pneumatic lines can have serious effects:
1) The water can collect in the compressed air manifold. When sufficient water is collector, it may “squirt” into the filter elements during a cleaning cycle. The drenching of the filter elements is intermittent, but the long term effect is higher pressure drop, more frequent cleaning and premature filter element replacement. Often the filter will dry itself from the exhaust flow through the collector. But residual effects from this wet dry cycling are cumulative. Cellulose cartridge filter elements are especially vulnerable as each wet cycle cause the permeability to increase and harmful effects are much faster.
2) If a collector is installed outdoors in below freezing conditions, even very small amounts of moisture droplets can condense on the diaphragms of air valves. The diaphragms will then stick to the seats of the valves and will not close. This will discharge all the air from the system since typically 150 to 400 SCFM can be discharged through the valve. Since these valves operate with internal pilot ports, the valve will not close until the supply pressure reaches 25 psig. There needs to be an external shutoff to get the collector (and sometimes associated compressed air supply) back to an operating mode.

QAM has a two different products to address these problems:
A) Manifold Tank Automatic Drain Valve System
B) Thermostatically control compressed air manifold heater. This system will allow the collector to operate even when the compressed air dryer is malfunctioning by turning any liquid moisture to water vapor.

QAM also provides dust collector retrofit and consulting services to help resolve common problems that no one else seems to have any solutions.